Broadband choke, siple, clamp on (2026_clamp_choke_pe)
For measurements I need simple clamp-on chokes.
Materials used:
- RG400 cable, 80cm long with N connectors.
- Clamp-on ferrite 0431176451 by Fair-rite. Material 31, inner diameter 18mm.
- Clamp-on ferrite ZCAT1730 by TDK, 6 pieces, inner diameter 7mm.
- 3D printed part to keep the windings at a defined spacing. Link to folder /step
I am satisfied: can be attached to a 5mm cable with already mounted connectors. Relatively compact.
|
Finished common-mode choke.
|
 |
|
Clamp-on ferrite and 3D printed part made of PETG.
|
 |
|
Large clamp-on ferrite, material 31.
|
 |
|
The cable is inserted, loops not yet pulled tight. The ferrite is clamped and the cables are
pulled out so that the windings sit snugly.
|
 |
|
Secured with cable ties
|
 |
|
|
 |
|
Measurement with NanoVNA V2 plus 4. Measurement without choke: "leads"
|
 |
|
Only large ferrite with 3 turns: "0431176451_n3"
|
 |
|
Complete filter: "0431176451_n3_and_6_zcat1730"
|
 |
|
Measurement of S21. A common method to measure chokes. The shield of the cable is connected.
At 160m band at -20 dB and even lower at higher frequencies.
The artifacts (dips) at higher frequencies are already visible in the measurement with only the lead cables. In the
final application, when the common-mode choke is between the measuring instrument and the antenna, the leads
are further apart and the isolation should be better than -30 dB.
|
 |
|